• Pneumatic Diaphragm Pump Damping Special Damper
  • Pneumatic Diaphragm Pump Damping Special Damper
  • Pneumatic Diaphragm Pump Damping Special Damper
  • Pneumatic Diaphragm Pump Damping Special Damper
  • Pneumatic Diaphragm Pump Damping Special Damper

Pneumatic Diaphragm Pump Damping Special Damper

Certification: ISO9001:2008, CE
Rated Current: Diaphragm
Voltage: Air
Material: Polypropylene
Power: Pneumatic
Valve Body Type: Diaphragm
Samples:
US$ 226/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Shanghai, China
to see all verified strength labels (23)

Basic Info.

Model NO.
HY-2L
Function
Air
Diaphragm Material
Polyethylene
Performance
Explosion
Transport Package
Carton
Specification
2L
Trademark
HYPV
Origin
Made in China
HS Code
8413501090
Production Capacity
1000PCS Per Months

Product Description

DSHELL MATERIAL

Can be customized

Pneumatic Diaphragm Pump Damping Special Damper

Product parameters
 

Model volume(L) High(mm) Diameter(mm) Caliber Preset Pressure Connection Size
HYMZ-0.35    0.35   235     142 DN15        1.6 1/2"
HYMZ-0.6    0.6   250     174 DN20        1.6 3/4"
HYMZ-1.0    1.0   310     210 DN25        1.6 1"
HYMZ-2.0    2.0   330     280 DN32        1.6 1 +1/4"
HYMZ-4.0    4.0   370     306 DN40        1.6 1+1/2" 
HYMZ-4.0    4.0   370     306 DN50         1.6 2"

Product can be customized according to your demands

Volume selection method:

Pulsation Damper volume = Every stroke volume (ml) *15

A PULSATION DAMPER
Pneumatic Diaphragm Pump Damping Special Damper

 

1. The ability to minimize pulsations, vibrations, and water hammer means that this component-
provides excellent protection and smooth system flow.

2. Protection of pipes, meters, valves and instrumentation from pulsation and vibration

3. Used together with back pressure valve can make pressure fluctuation close to zero.

4. Limit damaging pressure surges caused by pump start-up and shut-down.

5. Prevention of foaming and splashing

6. Allows more accurate readings when pumping through mass flow meters & other instruments
 

DESIGN FEATURES
Pneumatic Diaphragm Pump Damping Special Damper

The container is often divided into two sides by a flexible membrane , one containing compressibe nitrogen gas,
and the other side through which the liquid goes. Convenient maintenance, long-term stable operation


APPLICATION
 In a metering system constant flow is normally required. A damper is essential to reduce the flow fluctuations-
to ensure process control and mixing.  
In pipes pressure pulsation will shake the piping and dampening the pulses prevents fatigue and connection failures.
In general removing pulsation reduced the energy usage to transmit liquid over distances

Pneumatic Diaphragm Pump Damping Special Damper
 

Where is a Pulse Dampener installed ?

For best performance a Pulsation Dampener should be installed at the start of the pipe down-
which the flow has to be forced or when the dampener is to perform as a suction side acceleration head loss reducer,
then the installation is after the suction supply line at the entry to the pump inlet check valve.
Generally A pulsation dampner is installed as close to the source of the pulsation as possible.


Instructions
Pneumatic Diaphragm Pump Damping Special Damper


COMPANY INFOTMATION
Pneumatic Diaphragm Pump Damping Special Damper

FAQ

1. Q: Are you a factory or trading company?

      A: We are a factory.  

  2. Q: What're your payments ? 

      A: T/T,Western Union,L/C etc.

 3. Q: What about the package ?

     A: Standard export plywood case or carton.

 

If you want to know more details, Please send inquiry to me,


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
10
Year of Establishment
2006-01-11